Introduction

Principle & Structure 

Temperature principle: The thermal resistance signal of PT100 or PT1000 transmits the current signal through transportation and displays the current temperature value of the measured medium locally.

Pressure principle: Based on the principle of diffusion silicon, all stainless steel shell, waterproof design, used for liquid level measurement.

application

● Industrial field level measurement and control

● Ships and Navigation Systems

● Hydrological measurement and monitoring

● Urban and water supply

● Reservoir dam water level measurement

● Circulating water and sewage treatment system

Features

● -25~80℃ measurable medium temperature range

● The deepest can be immersed in 300m water

● Lightning protection design

● The protection grade of sensor parts is IP68, and the junction box is IP65&IP68

technical parameter

Medium temperature:25...80℃
0...80℃
Accuracy class:         Level 0.2
Pressure overload: Calibration level value 2 times
Cable material: PUR polyurethane rubber
stability:  Better than 0.2% FS per year
Temperature Effects: <±0.02%FS/K
Response time:  <1ms (10% to 90% range)
Operating Voltage:  12...36V DC
Load Resistance:0...750Ω
Current consumption:same as signal current
Electrical Protection:reverse pole
overload
Short circuit protection
Protection class:Sensor: IP68
Transmitter: IP68 (customized)
Transmitter: IP65
Shell material:Junction Box: Cast Aluminum
Junction Box: Stainless Steel
Probe: stainless steel 1.4435 (316L)
output signal:4...20mA
RS485

Selection table

TK90Input temperature transmitter (including liquid level)

temperature range

-25…80℃
0...80℃
Level range

The unit is meters (m) (for example: R10: represents a range of 10 meters)
cable length

The unit is meters (m) (for example: K12, cable 12 meters)
Install fixed mode

G1 male thread connection (*)
Direct doubling (no junction box and no process connection)
The screw hole is directly inserted without sealing (suitable for open bracket installation)
DN50 flange connection
Customized thread (the size needs to be larger than G1)
Outgoing method and display

Direct double line IP68
Standard wiring unit type IP65
LCD digital display IP65
Outgoing method and display

4~20mADC(*)
Probe Material

Stainless steel 1.4435(316L) (*)
(special option) VARIO

RS485 communication protocol (junction box material 304 stainless steel)
The complete data of this selection table, please contact the sales staff or email to sales@kewill-auto.cn for complete samples.
Remarks: (*) are in stock or standing.
Prev :TK71 Series Temperature Controller